Model CP650 Installation Manual B-Chain Alignment
4-6
u
pu
eve
s
>
>>
>Channel: Center
Level: xx
Room Level xx.x dB
Adj
us
t
O
u
t
pu
t
L
eve
l
Channel: Center
> Level: xx
Room Level 85.0
85.085.0
85.0 dB
u
pu
eve
s
Channel: Center
>Level: xx
Room Level xx.x dB
4.5 Initial Output-Level Calibration
Each of the channels should now be adjusted to give a reasonable sound pressure
level in the room. It is not necessary to get exact readings at this point because the
levels will change slightly during equalization of the room. Exact output level
adjustment will be performed after equalization.
Note: If pink noise is not being generated, this indicates that the status of the digital
input has changed. If you are using the digital input on the CP650, either disconnect
or power down the device attached the digital input during calibration. A change in
the digital input bitstream will cause the CP650 to mute the pink noise.
4.5.1 Main Channels
After auto-calibration, the Output Levels adjust
screen appears with Center Channel active.
Note: The RTA oscilloscope display is not active on this menu.
menu
OK
Press the center menu button, moving the cursor
down one line to Level:
Note: The Level: line on the display shows a relative number.
The number has no units.
Rotate the main fader knob to change the CP650
pink-noise output signal level into the auditorium
while watching the measured Room Level shown
on the bottom line of the display. Set it to 85 dB.
Note: If the room level does not appear, the calibration step may
have failed or was not performed. Repeat Section 4.4.