Dolby
®
Model CP650 Installation Manual Installation
2-7
For Non-EU Countries Only:
If it is necessary to use two- or four-conductor shielded cables, use the following
wiring diagrams.
Gnd
1
Gnd
Gnd
Gnd
Gnd
3
2
4
5
6
1
J1
J2
2
3
Out 2–
Out 1–
Out 2+
Out 1+
*
*
*
+
+
–
–
1
2
3
4
5
6
7
8
9
Cat.No.655 Wiring Diagram
Ground wire on pin 5, OPTIONAL
Ground wire on pin 2, REQUIRED
+Vdd
Vdd
–
Shield
Shield
Belden 8451
or equivalent
CP650
Optical In
Figure 2–5 Cell Preamp Wiring Using Two 2-Conductor Shielded (Screened) Cable
1
J2
J1
Gnd
Gnd
Gnd
Gnd
3
4
5
6
1
2
3
Out 2–
Out 1–
Out 2+
Out 1+
+
+
–
–
1
2
3
4
5
6
7
8
9
+Vdd
Vdd
–
Shield
Shield
Belden 8723
or equivalent
CP650
Optical In
Figure 2–6 Cell Preamp Wiring Using One 4-Conductor Shielded (Screened) Cable