Model CP650 Troubleshooting Chart Maintenance and Troubleshooting
9-16
Symptom Probable Cause Recommended Action
CHANGEOVER AND
CONTROL TROUBLES
Projector changeover command does not
change the sound to the output of the
selected projector and the front-panel
indicators P1 or P2 do not light according
to the projector selected.
Defective changeover relay or switch.
Defective wiring from relay or switch to terminals on rear
of the CP650.
Defective Cat. No. 772 board.
If possible, check that the relay or switch contacts actually
open and close as the changeover command is issued
several times.
Check that the wiring has not been damaged and that
connections are firmly made at both ends.
Call service engineer.
With an automation system connected to
the CP650:
The CP650 freezes into one format and
does not accept any other selected format
when you press the front-panel buttons.
Incorrect wiring to D-connector plugged into CP650;
defective or incorrectly programmed automation
equipment.
Unplug the D-connector from the back of the CP650. If
you can exercise local control over the CP650, the problem
is either the wiring to the automation equipment or the
automation equipment itself. Call service engineer.
If you cannot exercise local control over the CP650 even
with the automation equipment disconnected, switch to
bypass mode by pressing the front-panel power button, and
call service engineer.