Dolby Laboratories CP650 Installation Manual Page 174

  • Download
  • Add to my manuals
  • Print
  • Page
    / 184
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 173
Dolby
®
Model CP650 Installation Manual External Control of CP650
E-2
Commands
Key Range of Values Notes
format_button
0 .. 7
inticates which button on the CP650 front-panel
should be applied:
Data Button Applied
0 Format 01
1 Format 04
2 Format 05
3 Format 10
4 Format 11
5 User Format 1
6 User Format 2
7 Nonsync Format
Any Preset Fader Level associated with the indicated
button is also applied, and the LED for the selected
button is illuminated.
fader_level
0 .. 100
corresponding to fader values 0.0 ... 10.0
Querying fader_level while
the fader_setting is
“auditorium” returns the
level as determined by the
auditorium fader.
fader_setting
“local”
“auditorium
If “auditorium” is selected, the main shaft fader is
disabled as are any attached Remotes (Cat. No. 779,
Cat. No. 771).
<see above>
If changed via this serial
interface, this setting is lost
at the next CP650 restart.
mute
0 .. 2
indicating the desired mute setting:
Data Mute Operation
0 Unmute
1 Mute
2 Toggle
Any applicable “Fade In/Out Time” is applied just as if
the front-panel MUTE button were used.
user_formats
This key can only be
queried, not modified.
Querying this key returns
on one line a comma-
separated list indicating the
user formats:
<user 1>, <user 2>,
<nonsync>
projector
1 .. 2
This key can only be
queried, not modified.
preset_fader_level
This key can only be
queried, not modified.
Querying this key returns
on one line a comma-
separated list indicating the
current value for all format
buttons separated by
commas. The buttons are
listed in the following
order:
01, 04, 05, 10, 11, U1, U2,
NS
Each level can be 0–100, or
–1. A setting of –1 indicates
no preset fader level for
that button.