3-13
3.7 Power On
Connect the bypass power module to the CP500 and plug it into AC mains. The
unit is shipped with the POWER/BYPASS switch set to BYPASS. The front panel
BYPASS LED should light.
Open the front panel and confirm that one of the Projector Select LEDs is on.
Projector 1 or Projector 2 is selected by Jumper J2 on the Cat. No. 661 (See
manual section 3.4).
Connect the main power cable. Then, push the Bypass/Power button to turn on the
CP500.
When power is first applied, the first
screen that appears displays the revision
level of the software. Next, a brief
"Loading System" message is displayed.
In a few seconds, the Current Format
screen appears. This is the normal screen
that the projectionist or any other
operator would see and the only screen
they will need to see for ordinary
purposes.
Run quick checks to confirm that:
Rotating the front panel knob changes the numbers displayed next to it.
Pushing the MUTE button causes the MUTE LED to flash.
Pushing any of the buttons on each side of the display causes the mute LED to
go off and the LED next to the button pushed to go on (except buttons next to
" " on the display).