Dolby Laboratories CP500 Specifications Page 125

  • Download
  • Add to my manuals
  • Print
  • Page
    / 154
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 124
A-11
Saving System Settings
A.2.2 Using Load500 Software
Load500 is a specific DOS based program which has been developed to make the
task of transferring alignment and format information to and from a computer both
simpler and quicker. The program includes a special option which allows CP500
operating software to be updated easily from new files supplied on disc. Please
refer to the
Load500
software manual, for complete information on installation
requirements and operation.
Equipment Needed
The following minimum computer system and CP500 requirements are necessary
to successfully use Load500:
1.
An IBM/PC-compatible computer with a free serial port running MS-
DOS version 5.0 or greater.
2.
A direct connection serial cable (not null modem) to connect the
IBM/PC-compatible computer to the CP500.
3.
The CP500 to be upgraded must have 2Mbit flash ROM’s.
Transferring Data From the CP500 to the Computer
1. Connect the Serial Data port on the back of the CP500 to the computer’s serial
port using the cable described above.
2.
On the CP500, press
MENU
System Setup
CP500 Controls
Data Transfer
3. Once in the Data Transfer screen,
select “
Connect to Load500
”, then
press
OK
. The CP500 will display
the “
Waiting for connection
” box.
Connect to Load500