10-15
Symptom Probable Cause Recommended Action
CHANGEOVER AND
CONTROL TROUBLES
Projector changeover command does not
change to sound output of the selected
projector and the front panel LEDs do not
light according to the projector selected.
Defective changeover relay or switch.
Defective wiring from relay or switch to terminals on rear
of the CP500.
Defective Cat. No. 661 optical preamplifier.
If possible, check that the relay or switch contacts actually
open and close as the changeover command is issued
several times.
Check that the wiring has not been damaged and that
connections are firmly made at both ends.
Call service engineer.
With optional automation connected to the
CP500:
The CP500 freezes into one format and
does not accept any other selected format
when you press the front panel switches.
Incorrect wiring to D-connector plugged into CP500 or
defective or incorrectly programmed automation
equipment.
Unplug the D-connector from the back of the CP500. If
you can exercise local control over the CP500, the
problem is in either the wiring to the automation
equipment or the automation equipment itself. Call service
engineer.
If you cannot exercise local control over the CP500 even
with the automation equipment disconnected from the
CP500, switch to bypass and call service engineer.
With optional remote control unit Cat. No.
689 connected to the CP500:
The CP500 freezes into one format and
does not accept any other selected format
when you press the front panel switches.
Incorrect wiring to remote box connector plugged into
CP500 or defective Cat. No. 689.
Disconnect the Cat. No. 689 cable from the CP500. If you
can exercise local control over the CP500, the problem is
in either the wiring to the remote unit or the remote unit
itself. Call service engineer.
If you cannot exercise local control over the CP500, even
with the remote unit disconnected from the CP500, switch
to bypass and call service engineer.