CP650 Installation Manual
2-1
Chapter 2
Installation
The CP650 uses a universal switching power supply that can accommodate mains
voltages from 100–120 VAC, and 200–240 VAC, at frequencies from 50 to 60 Hz.
FB425M05.CDR
AC MAINS FUSE
BYPASS FUSE
FB425N05.CDR
AC MAINS FUSE
BYPASS FUSE
Figure 2-1 Fuse Locations on Units with Figure 2-2 Fuse Locations on Earlier
Internal Fuses Units with External Fuses
The CP650DC models do not include a bypass fuse.
2.1 Check Main Fuse
WARNING: Do not connect the CP650 to mains power until all other
connections have been made. Check that the correct main fuse has been
installed. To reduce the risk of fire, replace only with fuses of the same
type and rating.
The main power supply fuse is a 5 A (6.3 A on earlier units with external fuses),
250 V, 20 mm, time-lag, low-breaking capacity fuse.
Figure 2-3 Main Fuse Assembly—Earlier Units with External 6.3 A Fuses
Check that the fuse is of the correct rating. The fuse carrier must be inserted into the
compartment with the fuse oriented to the left. Do not force the carrier into the
Page view 20