8.4.5 Early Cat. No. 682 Output HF/LF Balance and Level
Adjustments
(With Cat. No. 683 Electronic Crossover Card)
REMEMBER:
Adjust the trimpot on the Cat. No. 682 Output Card for LF/HF Balance and the adjust the
trimpot on the Cat. No. 683 for Bypass Level.
Thread the projector, and run a loop of
Cat. No. 69P pink noise test film, or the
pink noise side of Cat. No. 69 test film.
System Setup
key
Format
Selection
Menu
key
screen shows:
press:
Menu
Selection
screen shows:
press:
Format 04 Dolby Stereo
FORMATS
Menu Cancel OK
Exit
Select
Format 04
(Dolby Stereo).
Press
MENU
. Then,
System Setup
.
Press
Bypass
(SK8). This connects the
Left, Center, and Right outputs of the
CP500 to the Bypass subsystem output.
CAT. NO. 682
CENTER
BYPASS
Adjust the Bypass trimpot on the
Cat.
No. 682
(be sure not to adjust the Cat.
No. 683 at this time) so that the average
level displayed on the external spectrum
analyzer (you cannot use the CP500’s
internal analyzer for this adjustment)
from 200 to 500 Hz is equal to that from
630 Hz to 3 kHz.
This trimpot adjusts the low frequency
driver level relative to the high
frequency driver. In general, the Bypass
Gain Range jumper on the Cat. No. 682
card should be set to HI and the Cat.
No. 683 card should be set to LO. If you
cannot get the desired result, change the
setting of the appropriate jumper.
SK8
Using the
Bypass
key (SK8), toggle
back and forth between regular and
bypass operation, setting the Bypass
level trimpot on the
Cat. No. 683
so
that the sound pressure level matches
between Bypass and non-Bypass
operation.
SK8
FORMATS
Turn the bypass feature off. Press
FORMATS
to return to the
Format
screen.