8-5
8.3 Setting Digital Surround Delay
The CP500 automatically calculates a typical digital surround delay based on the
optical surround delay setting performed in Section 8.1. Actual theater geometry
affects the amount of surround delay required, therefore you may wish to set the
delay manually.
From the System Alignment menu, press the Digital Surround Delay key (SK5).
Rotate the front panel knob until the desired delay reading is displayed, then press
OK.
The following tables show approximate delay values (in milliseconds) based on
theater width and length. Setting of surround delay should be verified by listening at
various locations in the theater.
Width (feet)
20 30 40 50 60 70 80 90 100 110 120 130 140
20
10 10 10 10 10 10 10 10 10 10 10 10 10
30
10 10 10 10 10 10 10 10 10 10 10 10 10
40
20 20 20 20 20 20 20 20 20 20 20 20 20
50
30 20 20 20 20 20 20 20 20 20 20 20 20
60
30 30 30 30 30 30 30 30 30 30 30 30 30
70
40 30 30 30 30 30 30 30 30 30 30 30 30
80
50 40 40 40 40 40 40 40 40 40 40 40 40
Length 90
50 50 40 40 40 40 40 40 40 40 40 40 40
(feet) 100
60 50 50 50 50 50 50 50 50 50 50 50 50
110
70 60 60 50 50 50 50 50 50 50 50 50 50
120
70 70 60 60 50 50 50 50 50 50 50 50 50
130
80 80 70 70 60 60 60 60 60 60 60 60 60
140
90 80 80 70 70 60 60 60 60 60 60 60 60
150
90 90 80 80 80 70 70 70 70 70 70 70 70
160
100 100 90 90 80 80 70 70 70 70 70 70 70
170
110 100 100 90 90 80 80 80 80 80 80 80 80
180
110 110 100 100 100 90 90 80 80 80 80 80 80
190
120 120 110 110 100 100 90 90 90 90 90 90 90
200
130 120 120 110 110 100 100 100 90 90 90 90 90
Width (meters)
10 15 20 25 30 35 40 45 50
10
20 20 20 20 20 20 20 20 20
15
20 20 20 20 20 20 20 20 20
20
30 30 30 30 30 30 30 30 30
25
40 40 40 40 40 40 40 40 40
30
50 50 50 50 50 50 50 50 50
35
60 60 50 50 50 50 50 50 50
40
80 70 60 60 60 60 60 60 60
Length 45
90 80 70 70 70 70 70 70 70
(meters) 50
100 90 80 80 80 80 80 80 80
55
110 100 90 90 80 80 80 80 80
60
120 110 110 100 90 90 90 90 90
65
130 120 120 110 100 100 100 100 100
70
140 140 130 120 110 110 110 110 110
75
150 150 140 130 120 120 110 110 110