10-12
Symptom Probable Cause Recommended Action
TROUBLE IN ONE OR
MORE CHANNELS
One channel fails. Defective power amplifier, external crossover, or
wiring for that channel.
Malfunctioning module in CP500.
Place the CP500 in bypass. All three screen speakers should
become active. If not, there is a fault in the power amplifier,
external crossover, or wiring for the missing channel.
Check if the amplifier concerned is on and check for blown
fuses.
Check that the wiring from the CP500 to the amplifier or the
loudspeaker wiring have not been broken or disconnected; check
that the screws connecting the wiring on the back panel are
properly tightened..
If the power amplifier and the wiring are satisfactory, the
problem is a malfunctioning module in the CP500; switch to
bypass and call service engineer.
The sound from one channel is distorted
(you can detect the distortion at the booth
monitor at normal listening level).
Defective power amplifier for that channel.
Defective speaker for that channel. (Booth sound
is OK but sound in the auditorium is bad).
Malfunctioning card in CP500.
Wiring from the stereo solar cell to the CP500.
Check if amplifier is on and if its fuse(s) is OK.
Check speaker.
Check that the cards are all properly seated in their connectors.
Check that the wiring from the stereo solar cell to the CP500 has
not become damaged and that the solder connections to the
fanning strip are secure. Check that the D connector for the solar
cell is firmly plugged into the CP500.
Call service engineer if wiring problems are found.