Dolby Laboratories CP500-300 Installation Manual Page 86

  • Download
  • Add to my manuals
  • Print
  • Page
    / 86
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 85
D.2
D connector J18
1 S0 [automation select] fmt 01 Mono
2 S1 [automation select] fmt 04 Dolby A-type
3 S2 [automation select] fmt 05 Dolby SR [optical]
4 S3 [automation select] fmt 60 non-sync via matrix
5 S4 [automation select] fmt 10 Digital
6 S5 [automation select] fmt 42 mag aux with NR
7 S6 [automation select] fmt 60 non-sync standard
8 S7 [automation select] fmt 22 mag aux without NR
9 [automation select] “remote/local” fader
10 [automation select] mute
11 “-15 volts”
12 ground
13 “+15 volts”
14 ID0 [automation indicator] fmt 01 Mono
15 ID1 [automation indicator] fmt 04 Dolby A-type
16 ID2 [automation indicator] fmt 05 Dolby Stereo SR [optical]
17 ID3 [automation indicator] fmt 60 non-sync via matrix
18 ID4 [automation indicator] fmt 10 Dolby Stereo Digital
19 ID5 [automation indicator] fmt 42 mag aux with NR
20 ID6 [automation indicator] fmt 60 non-sync standard
21 ID7 [automation indicator] fmt 22 mag aux without NR
22 IDF local [automation indicator] “remote/local” fader
23 IDF mute [automation indicator] mute
24 connection to Cat. No. 384
25 projector changeover status logic o/p