Dolby Laboratories CP500-300 Installation Manual Page 65

  • Download
  • Add to my manuals
  • Print
  • Page
    / 86
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 64
Action
Indication
Step
No.
5-48
B-Chain Alignment Procedures
60
non-sync
1
4
2
4
3
NORMAL BYPASS
0
1
2
3
4
5
6
7
8
9
10
select
local/remote
mute
local active
h. Adjustment of Non-sync Gain
B-Chain Alignment Procedures
Notes
5-49
h. Adjustment of Non-sync Gain
Connect a cassette deck or CD player to the from non sync terminals on terminal block
TB1 on the backplane of the CP65.
Press the format 60 non sync switch.
Place the NORMAL/BYPASS switch in the NORMAL position.
Set the FADER to the 7 setting.
Check that the local FADER is selected the local active LED on the CP65 is lit. If
necessary, select the local FADER by pressing the select local/remote switch.
Page view 64