Dolby Laboratories CP500-300 Installation Manual Page 45

  • Download
  • Add to my manuals
  • Print
  • Page
    / 86
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 44
B-Chain Alignment Procedures
Action
Indication
Step
No.
5-8
0
1
2
3
4
5
6
7
8
9
10
select
local/remote
mute
local active
a. Setting Room Equalization
0
1
2
3
4
5
6
7
8
9
10
NORMAL BYPASS
0
1
2
3
4
5
6
7
8
9
10
select
local/remote
mute
local active
04
Dolby Stereo
A-type
auto
subwoofer
off
CAT. NO. 441
Subwoofer
off
8
9
10
11
B-Chain Alignment Procedures
Notes
5-9
a. Setting Room Equalization
Set the FADER to the 0 position.
Verify that the fader local active LED is on. If necessary, press the select local/remote
switch.
Press the 04 Dolby Stereo A-type switch; the LED in the switch should light.
If a Cat No. 441 Surround Equalizer, Subwoofer card is fitted set the
subwoofer switch to the OFF position.
Set the NORMAL/BYPASS switch to the NORMAL position.
Switch on the center channel pink noise on the Cat. No. 85 Pink Noise Generator (C switch
up or down).
Slowly advance the FADER control to position 7. You should hear pink noise.