Understanding the Log and the Graph
Inbetween,theloglistsseveralattributesforeachsecondofrealtime:
•Timecode:Indicatesthesecti onofthefilemeasured
•Date:Indicatesthecalendardateonwhichthemeasurementwasmade
•Timeofday:Indicatesthetimeofdaythemeasurementwasmade
Dialoguepresent:Indicatesthechannelsthatcontaineddialogueornodi
alogue
•Themeasurementsyouchose
•Thewarningsyouchose
•Peak(dBFS):Indicatesthelargestpeakvaluemeasuredinthesection
•Peakcount:Indicatesthenumberofpeaksinthesectionthatexceededthepeakcount
thresholdvalue
Thelogalwaysdisplaysmeasurementswiththeprecisionoftenthsofaunit.
5.2 Viewing the Graph
AsshowninFigure 53,DolbyMediaMeter2cangraphuptosixmeasurementsofthe
selectedfile:
Infinite Dialogue(withDialogueIntelligenceon)
Short Term Dialogue(withDialogueIntelligenceon)
Dialogue Range(withDialogueIntelligenceon)
Infinite All(withDialogueIntelligenceoff)
Short Term All(withDialogueIntelligenceoff)
Sample PeakorTrue Peak(dependingonyourconfigurationchoice)
Figure53
Figure 5-3 Sample Graph
Note: Themeasuredpeakvalueisanoverallpeak,notrelatedtotheselectionof