4-8
Symptom Probable Cause Recommended Action
NO SOUND IN SOME
FORMATS
No analog film sound (Formats 01,04,
05). Front panel normal, but Dolby
Digital sound OK and non-sync OK.
The analog exciter lamp or power supply may have failed
or the wrong projector may be selected. Solar cell
connections may be loose or damaged. The Cat. No. 661
optical preamp may have failed.
If signal present LEDs on the Cat. No. 661 (J3) are not
flashing, verify exciter operation and solar cell connections
as described above. Substitute known good Cat. No. 661.
No Dolby Digital sound (Format 10).
Front panel normal, analog sound OK.
Digital exciter lamp/LED not working,
Digital subsystem, non-Dolby Digital print being played,
film not threaded correctly in reader, reader failure
Verify that the exciter lamp or LED in the digital reader is
on and that the print you are playing has Dolby Digital
information on it and is correctly threaded through the
digital reader. If the CP500 will still accept a Format 10
command, the DA20 subsystem is probably still working.
No sound on external six track input
(Format 11, 70mm, external DA20, or
other multi-channel sound sources)
Front panel normal.
Cat No. 685 card defective. Wrong format, external
device not receiving good data.
Check external device for audio output. Substitute known
good Cat. No. 685.
No sound in non-sync
Non-sync source not working, non-sync level pots too far
down (on Cat. No. 681 card), faulty Cat. No. 681. If non-
sync is a user format, is the input from Non-sync 1 or
Non-sync 2? Which channels are the signals being sent
to? Are those power amplifiers working?
Verify output of non-sync source. Determine from front
panel meters which channels the output is directed to and
verify that power amplifiers and speakers for those
channels are working. After checking the above, adjust
non-sync level pots on Cat. No. 681, turning both left and
right channels by equal amounts.
Red Bypass LED lit. Front panel dark.
There is sound.
System is in Bypass operation. Turn on the CP500 with the push switch at the lower right
hand corner behind the front door. Check that the power
cord to CP500 is securely plugged in to a working power
source. Check fuse behind plastic door on AC mains power
inlet module of CP500. Call service engineer if none of
these steps fixes the problem.